Description
เครื่องวัดออกซิเจนในอากาศ Oxygen (O2 ) Gas Sensor เซ็นเซอร์ O2 Sensor (Oxygen Gas Detector) สำหรับเครื่องตรวจวัดออกซิเจน Oxygen Sensor from CiTiCel®, England
|
Oxygen Sensor from CiTiCel®, Made In England
เซ็นเซอร์ตรวจวัดออกซิเจน มาตราฐาน ผลิตจากประเทศอังกฤษ
|
O2 Sensor: Digital Oxygen Indicator (O2 Meter) Sensor, ยี่ห้อ CiTiCel®, England
|
เครื่องวัดออกซิเจนในอากาศ Digital oxygen indicator Oxygen CiTiceL®
Features:
- False alarm immunity
- Enhanced response time in extreme applications
- Reliably meets stated life
- Superior environmental performance
Specification:
| MEASUREMENT | |
| Technology | Electrochemical |
| Measurement Range | 1–25% vol. O2 |
| Maximum Overload | 30% vol. O2 |
| Output Signal* | 0.10 ± 0.02 mA in Air |
| Response Time (T90)* | <15 Seconds |
| Zero Current (Offset)* | <0.6% vol. O2 |
| Linearity | Can be considered linear in many cases. See Operating Principles (OP-02) for further details. |
| ELECTRICAL | |
| Recommended Load Resistor | 100 Ω |
| MECHANICAL | |
| Casing Material | ABS |
| Weight | <16 g |
| Orientation Sensitivity | <0.2% vol. O2 equivalent |
| ENVIRONMENTAL | |
| Operating Temperature Range | -20°C to +50°C (up to 3 months continuous across RH range) |
| Recommended Storage Temp | 0°C to 20°C |
| Thermal Transient (Temp. plunge +22°C to -20°C) |
<23.5% vol. O2 |
| Operating Pressure Range | Atmospheric ± 20% |
| Pressure Coefficient | <0.02% signal/mbar |
| Pressure Transient (60 cm H O step change) |
<200% signal change |
| Relative Humidity Range Continuous Short Term |
(at 0°C to 20°C) 5 to 95%RH non-condensing 0 to 99%RH non-condensing |
| LIFETIME | |
| Long Term Output Drift* | <2% signal/month Typically <5% over operating life |
| Expected Operating Life | Minimum 24 months in air |
| Storage Life | 6 months in original packaging 24 months from date of despatch |
| * Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time. | |
Applications:
• Oxygen manufacturing workshop
• Petroleum refining and petrochemical plants
• Oxygen content detecting in trains and automobiles
• Oxygen content detecting in minerals
• Oxygen content detecting during mountain climbing and in sealed places
• Other industries and plants using oxygen.
• Petroleum refining and petrochemical plants
• Oxygen content detecting in trains and automobiles
• Oxygen content detecting in minerals
• Oxygen content detecting during mountain climbing and in sealed places
• Other industries and plants using oxygen.